Preparation

Before installing the electric retractable door, the following preparations need to be made:

1. Confirm the size of the door opening: measure the size of the door opening according to the actual needs, so as to choose the appropriate electric retractable door.

2. Prepare tools: Prepare basic tools required for installation, such as electric drills, screwdrivers, wrenches, etc.

3. Check the power supply: confirm that there is a suitable power supply in the installation location in order to provide power for the electric retractable door.

4. Read the manual: read the installation manual of the electric retractable door carefully to understand the installation process and precautions.

740e3e0f4f368f7c3184f0e240b4fef.jpg

Installation Steps

1. Determine the installation position: determine the installation position of the electric retractable door according to the actual needs, and ensure that the size of the door opening matches the electric retractable door.

2. Install the track: according to the requirements of the manual, fix the track on the wall on both sides of the door opening, and pay attention to keep the horizontal and vertical of the track, so as not to affect the operation of the electric retractable door.

3. Install the driving device: Place the driving device at one end of the track, and connect the power supply and the driving device according to the manual.

4. Install the door body: put the electric telescopic door into the track to ensure that the door body is closely fit with the track and there is no obvious gap.

5. Connection control system: According to the requirements of the manual, connect the control system of the electric telescopic door, including remote control, sensor, etc.

6. Debugging and testing: After the installation is completed, debugging and testing are carried out to ensure that the electric telescopic door runs smoothly and without jamming.

de8a56b32379246766b59398a15c31b.jpg

Installation precautions

1. Follow the instructions: During the installation process, be sure to follow the installation instructions of the electric retractable door, and do not change the installation steps at will.

2. Ensure the safety of the power supply: During the installation process, pay attention to the safety of the power supply, ensure that the power supply is wired correctly, and avoid the risk of electric shock.

3. Keep horizontal and vertical: When installing the track, it is necessary to ensure the horizontal and vertical of the track, so as not to affect the operation of the electric retractable door.

4. Pay attention to fixing firmly: During the installation process, make sure that each component is fixed firmly to avoid loosening.

5. Debugging test: After the installation is completed, it must be debugged and tested to ensure that the electric telescopic door is running normally.

Common problems and solutions

1. The operation of the electric retractable door is not smooth: it may be caused by the track is not horizontal or vertical, and the position of the track needs to be readjusted.

2. There is abnormal noise when the electric telescopic door is running: it may be caused by loose parts or insufficient lubrication, and it is necessary to check and tighten the parts and add lubricating oil appropriately.

3. The remote control cannot control the electric retractable door: it may be caused by insufficient battery power or interference of the remote control signal, and the battery needs to be replaced or the position of the remote control needs to be adjusted.

4. The electric retractable door cannot be closed automatically: it may be caused by sensor failure or setting problems, and it is necessary to check whether the sensor is damaged or adjust the settings.

ce7573368c8f648b3edea63eca0199e.png

Care & Maintenance

In order to ensure the normal operation and prolongation of the service life of the electric retractable door, the following service and maintenance work is required:

1. Regular inspection: Regularly check all parts of the electric retractable door to ensure that it is firmly fixed and free of damage.

2. Clean up the track: regularly clean up the debris in the track and keep the track clean.

3. Lubrication and maintenance: Lubricate and maintain the electric telescopic door regularly, and add lubricating oil to ensure smooth operation.

4. Waterproof and moisture-proof: pay attention to waterproof and moisture-proof to avoid the failure of the electric telescopic door due to moisture.

5. Professional maintenance: If you encounter problems that cannot be solved, please contact professional maintenance personnel in time to deal with them.

This article introduces in detail the installation steps and precautions of the electric retractable door, hoping to help readers better understand and master the installation skills of the electric retractable door, in the installation process, be sure to follow the installation instructions, ensure that the installation work is completed safely and correctly, and carry out regular maintenance and maintenance to ensure the normal operation of the electric retractable door and prolong the service life.